Resumen en español · Traducción disponible

PróximaObligatoria

GB24788-2025

Safety technical requirements for medical gloves

医用手套安全技术要求

GB 24788-2025 es una norma nacional china obligatoria de próxima entrada en vigor: Safety technical requirements for medical gloves. Sector: Electrónica. Enfoque: Seguridad de productos. Entrada en vigor: 1 jun 2028.

La aplicabilidad depende del alcance del producto, la vía de certificación, los avisos de la autoridad competente y las reglas de transición. Solicite una traducción o verifique la fuente antes de usar esta ficha en una decisión de cumplimiento.

Resumen de cumplimiento

Este resumen está disponible por ahora solo en inglés.

Alcance y aplicabilidad

This standard specifies the safety technical requirements for medical gloves. It applies to single-use medical rubber examination gloves, single-use sterile rubber surgical gloves, single-use non-sterile rubber surgical gloves, and single-use polyvinyl chloride (PVC) medical examination gloves. Manufacturers of these specific medical glove categories must comply with this standard. It replaces the previous GB 24788-2009.

Requisitos técnicos

The standard outlines critical safety parameters for medical gloves, focusing on biological and chemical safety. It specifies water-extractable protein limits for gloves made from natural rubber latex to minimize allergy risks. Additionally, it defines surface residual powder limits, distinguishing between powdered and powder-free gloves, though this specific requirement does not apply to PVC examination gloves. The standard also introduces microbial limits for non-sterile gloves and mandates that sterilized gloves must be completely sterile. Finally, it sets strict ethylene oxide residue limits for gloves sterilized using this method. Compliance with these chemical and biological thresholds is mandatory for market access.

Métodos de ensayo

Testing procedures are defined to verify compliance with the technical requirements. Water-extractable protein content is determined using the modified Lowry method as per GB/T 21870-2008. Surface residual powder is measured according to GB/T 21869-2008, which includes a specific formula for calculating glove surface area. Microbial testing for non-sterile gloves follows GB 15979-2024, while sterility testing for sterilized gloves adheres to the Pharmacopoeia of the People's Republic of China. Ethylene oxide residue is tested according to GB/T 14233.1-2022. Accurate execution of these referenced methods is essential for valid compliance certification.

Preguntas frecuentes

What products are regulated under GB 24788-2025?

It regulates single-use medical rubber examination gloves, sterile and non-sterile rubber surgical gloves, and single-use PVC medical examination gloves.

What are the key updates in GB 24788-2025 compared to the 2009 version?

The 2025 version updates the residual powder limits for powdered gloves, adds requirements for microbial indicators and ethylene oxide residues, and modifies the glove surface area calculation formula.

Does the surface residual powder limit apply to all medical gloves?

No, the surface residual powder limit does not apply to single-use polyvinyl chloride (PVC) medical examination gloves.

The summary above provides a high-level overview of GB 24788-2025. To ensure complete compliance for your products entering the Chinese market, a precise and professional translation of the full technical specifications is essential. Purchase our high-quality English translation of GB 24788-2025 today to access all detailed parameters, tables, and testing procedures.

Indicaciones de aplicabilidad

Tipo
Producto
CCS
G45
ICS
11.140
Organismo competente
Ministry of Industry and Information Technology
Comité técnico
National Technical Committee on Rubber and Rubber Products of Standardization Administration of China

Relaciones

Sustituye a:GB 24788-2009 (Vigente)