한국어 요약 · 번역 의뢰 가능

현행강제

GB14287.3-2014

Electrical fire monitoring system―Part 3: Temperature sensing electrical fire monitoring detectors

电气火灾监控系统 第3部分:测温式电气火灾监控探测器

GB 14287.3-2014은(는) 현행 중국 강제 국가 표준입니다: Electrical fire monitoring system―Part 3: Temperature sensing electrical fire monitoring detectors. 산업: 전자. 주제: 제품 안전. 시행일: 2015년 6월 1일.

적용 여부는 제품 범위, 인증 경로, 주관 당국 공고, 전환 규정에 따라 달라집니다. 컴플라이언스 판단에 사용하기 전에 번역을 의뢰하거나 공식 출처를 확인하세요.

컴플라이언스 개요

이 개요는 현재 영어로만 제공됩니다.

적용 범위

This standard applies to temperature sensing electrical fire monitoring detectors used in electrical fire monitoring systems. It is mandatory for manufacturers producing these specific fire safety devices for the Chinese market. The scope includes independent and non-independent detectors, as well as contact and non-contact types, but excludes residual current detectors covered under GB 14287.2.

기술 요구 사항

The standard specifies mandatory requirements for basic performance, including alarm response times and temperature setting ranges. Detectors must issue an alarm within 40 seconds when the monitored temperature reaches the set value. It also defines monitoring alarm functions, requiring distinct audible and visual signals with specific sound pressure levels. Furthermore, the standard outlines stringent electromagnetic compatibility (EMC) and environmental tolerance criteria, ensuring reliable operation under various electrical and climatic conditions as per GB 16838.

시험 방법

Testing procedures evaluate the detector's basic performance and alarm functionality under controlled temperature changes. Manufacturers must verify compliance through a series of rigorous electrical and environmental tests. Key tests include insulation resistance, electrical strength, and various EMC immunity tests referencing the GB/T 17626 series. Additionally, climatic and mechanical tests such as low temperature operation and constant damp heat are required.

자주 묻는 질문

What products are regulated under GB 14287.3-2014?

It regulates temperature sensing electrical fire monitoring detectors, including independent, non-independent, and multi-sensor combination types.

Are there any updates from the previous version of GB 14287.3?

Yes, the 2014 version adds several tests, including leakage current, EMC immunity (RF, ESD, EFT, surge), and vibration tests, while canceling withstanding voltage, high temperature, and corrosion tests from the 2005 version.

Is GB 14287.3-2014 mandatory?

Yes, Chapters 5, 7, and 8 are mandatory. Compliance is required for market access in China.

The summary above provides a high-level overview of GB 14287.3-2014. To ensure complete compliance for your products entering the Chinese market, a precise and professional translation of the full technical specifications is essential. Purchase our high-quality English translation of GB 14287.3-2014 today to access all detailed parameters, tables, and testing procedures.

적용 참고 사항

유형
제품
CCS
C81
ICS
13.220.20
주관 부처
National Fire and Rescue Administration
기술 위원회
National Technical Committee on Fire Protection of Standardization Administration of China

관련 표준

대체 대상:GB 14287.3-2005