Resumo em português · Tradução disponível

VigenteObrigatória

GB6951-1986

Safe surface voltage of light fuel oil in tank filling operation

轻质油品装油安全油面电位值

GB 6951-1986 é uma norma nacional chinesa obrigatória vigente: Safe surface voltage of light fuel oil in tank filling operation. Setor: Meio ambiente. Foco: Segurança de produtos. Entrada em vigor: 1 de set. de 1987.

A aplicabilidade depende do escopo do produto, da via de certificação, dos avisos da autoridade competente e das regras de transição. Solicite uma tradução ou verifique a fonte antes de usar este registro em uma decisão de conformidade.

Visão geral de conformidade

Esta visão geral está disponível por enquanto apenas em inglês.

Escopo e aplicabilidade

This standard specifies the safe surface voltage for light fuel oils such as gasoline, kerosene, and diesel when filling metal containers like oil tanks, railway tank cars, and tank trucks. It is mandatory for operations involving these specific petroleum products. The standard does not apply to metal containers with suspended insulated conductors in the upper space, solid insulating objects inside, or when the oil surface contains hydrogen gas.

Requisitos técnicos

The standard establishes the critical safety threshold to prevent ignition or explosion of flammable vapors during the transfer of light petroleum products. It defines the maximum allowable electrostatic potential that can accumulate on the oil surface due to friction during pumping operations. The core requirement mandates that the maximum surface voltage must not exceed the specified safety limit. It categorizes the potential into three types: surface voltage, maximum surface voltage, and safe surface voltage. The safe value is defined as the threshold where, even if a discharge to ground occurs, it will not ignite the explosive mixture of oil vapor and air within the explosive concentration range. The standard explicitly sets the safe surface voltage value at 12000V. Compliance with this limit is essential for fire and explosion prevention in fuel handling facilities.

Métodos de ensaio

The standard outlines a specific measurement method using an insulated copper ball as a collecting electrode placed on the oil surface. The procedure requires verifying the system's ground insulation resistance and capacitance before measurement. It involves specialized equipment including an ultra-high resistance meter, a small capacitance measuring instrument, and an electrostatic potentiometer to accurately capture the maximum voltage during the filling process.

Perguntas frequentes

What products are regulated under GB 6951-1986?

It regulates light fuel oils including gasoline, kerosene, and diesel when loaded into metal containers such as oil tanks and tank trucks.

What is the safe surface voltage limit specified in GB 6951-1986?

The standard specifies a safe surface voltage limit of 12000V to prevent ignition of flammable vapors.

Are there any exclusions to the applicability of GB 6951-1986?

Yes, it does not apply to containers with suspended insulated conductors, solid insulating objects inside, or if the oil surface contains hydrogen gas.

The summary above provides a high-level overview of GB 6951-1986. To ensure complete compliance for your products entering the Chinese market, a precise and professional translation of the full technical specifications is essential. Purchase our high-quality English translation of GB 6951-1986 today to access all detailed parameters, tables, and testing procedures.

Indicações de aplicabilidade

Tipo
Segurança
CCS
C66
ICS
75.160.20
Órgão competente
National Energy Administration
Comitê técnico
National Energy Administration