GB26969-2011
Minimum allowable values of energy efficiency and energy efficiency grades for domestic solar water heating systems
家用太阳能热水系统能效限定值及能效等级
GB 26969-2011 is a current mandatory Chinese national standard for Minimum allowable values of energy efficiency and energy efficiency grades for domestic solar water heating systems. It appears in the Construction compliance cluster with a energy efficiency focus and has an implementation date of Aug 1, 2012.
Applicability depends on product scope, certification route, competent authority notices and transition rules. Requst for the translation or verify source before using this record in a compliance decision.
Compliance overview
Scope and applicability
This standard applies to domestic solar water heating systems with a heat storage water tank volume of less than 0.6m³. It covers various types including compact, separate direct, separate indirect, and integral collector storage (ICS) systems. It is essential for manufacturers to ensure their solar water heating products meet the mandatory energy efficiency limits before entering the Chinese market.
Technical requirements
The standard establishes the energy efficiency grades for domestic solar water heating systems, categorized into Grade 1, Grade 2, and Grade 3, with Grade 1 representing the highest efficiency. It introduces the Coefficient of Thermal Performance (CTP), which is calculated based on the ratio of daily useful heat gain and the average heat loss factor. Specifically, the standard defines the minimum allowable values of energy efficiency as Grade 3, which is a mandatory requirement. Products failing to meet this threshold are not permitted for manufacture or sale. Additionally, the evaluating values of energy conservation are set at Grade 2, serving as a benchmark for energy-saving products. Manufacturers must ensure their products meet at least Grade 3 requirements to comply with Chinese regulations.
Testing methods
The evaluation of energy efficiency relies on testing the daily useful heat gain per unit contour aperture area and the average heat loss factor. These parameters must be tested according to the procedures outlined in referenced standards such as GB/T 19141, GB/T 18708, GB/T 26970, and GB/T 26971. Accurate testing under specified conditions is crucial for determining the correct CTP and subsequent energy efficiency grade.
FAQs
What products are regulated under GB 26969-2011?
It regulates domestic solar water heating systems with a storage tank volume under 0.6m³, including compact, separate, and integral collector storage systems.
Is GB 26969-2011 a mandatory standard?
While most of the standard is recommended, Section 5.3 regarding the minimum allowable values of energy efficiency (Grade 3) is mandatory. Products not meeting Grade 3 cannot be sold in China.
How is the energy efficiency grade determined?
The grade is determined by calculating the Coefficient of Thermal Performance (CTP), which integrates the tested daily useful heat gain and average heat loss factor against standard minimums.
The summary above provides a high-level overview of GB 26969-2011. To ensure complete compliance for your products entering the Chinese market, a precise and professional translation of the full technical specifications is essential. Purchase our high-quality English translation of GB 26969-2011 today to access all detailed parameters, calculation formulas, and testing procedures.
Applicability hints
- Type
- Management
- CCS
- F12
- ICS
- 27.160
- Competent department
- Standardization Administration of China
- Technical committee
- National Technical Committee on Energy Fundamentals and Management of Standardization Administration of China
Relationships
Replaced by:GB 26969-2025 (Upcoming)